MSK-9 Positive Displacement Injection Thin Oil Distributor

The Positive Displacement Jet Valve MSK is a jet valve used in a variety of industrial applications. It is designed to provide a precise spray of fluid. These valves are used for accurate and reliable fluid delivery, typically in lubrication systems.

Описание

Особенность

Volume of Various Discharges: Can be availed with a difference in models, the stroke volume ranges from 0.03 to 0.5 ml.
Operate under High Pressures: Operating pressure could be as high as 1.0 MPa.
Quick Reset: Reset pressure is 0.3 MPa, enabling quicker recovery between cycles.

Construction: Distributor made of brass, hence robust and resistant to wear.
Maintenance-Friendly: Easy assembly and disassembly are designed to make maintenance as straightforward as possible, with minimum loss of production.
Corrosion Resistance: Construction materials ensure resistance to corrosion, enabling the valve to last long in adverse environments.
Customizable: The distributor is also available in various sizes and specifications that meet the different needs and requirements of any application.

Спецификация

Принцип действия Форсунка объемного впрыска
Количество торговых точек 1~12
Количество измеряемых веществ 0,03, 0,05, 0,13, 0,20, 0,30, 0,50 мл/цикл
Смазка 15-90 сСт при 40℃
Рабочая температура от -20 до +80 °С
Рабочее давление Минимум 1,0 МПа
Материал Медь, алюминий
Соединительная розетка Вход Rc1/8, Выход Φ4(Rc1/8)
Выходная арматура Тип рукава, Быстрый тип
Монтажное положение Любой

Testing

Visual Inspection: Inspect the injector and all of its connections for any signs of damage or leakage.
Pressure Test: Connect the injector to a pressure source and increase the pressure gradually to the operating level of 1.0 MPa. Look for leaks or other abnormalities.
Flow Test: Measure the volume discharged to verify that it falls within the range of 0.03 to 0.5 ml per stroke. This can be accomplished by utilizing a calibrated measuring device.
Reset Test: Check that the injector resets correctly at the set reset pressure of 0.3 MPa.
Operational Test: Run the injector through several cycles to ensure consistency in performance and check for any irregularities in operation.

Руководства