J200-3R Single-Line Lubrication Pump For Precise Lubrication
J200 is a highly efficient lubrication device with features including: DC24V power supply, 7ml/min discharge volume and 5-8MPa discharge pressure. It is suitable for a variety of industrial applications to ensure long-term stable operation of the equipment.
Deskripsi
Fitur
– Precise lubrication delivery: precise delivery of small amounts of lubricant is achieved through metering valves to ensure precise lubrication of each lubrication point of the machine.
– Liquid level switch: integrated in the cartridge adapter, it can stop the pump in time when the cartridge is out of oil, effectively prevent air from mixing into the lubrication system and ensure lubrication effect.
– Easy cartridge replacement: it needs to be carried out according to the steps, such as rotating to remove the old cartridge, installing the new cartridge and tightening the cover.
– Removable reservoir: optional removable reservoir version, no need to replace the cartridge to achieve simple repeated grease filling.
– Strong environmental adaptability: it can work under ambient temperature 0 – 50°C and humidity 35 – 85%RH, and the vibration requirement is below 9G (88m/s²), which can resist the influence of adverse environmental factors such as water, oil, debris, dust, etc. to a certain extent.
Spesifikasi
Model | J200-3D |
Waktu pelumasan | PLC atau pengontrol eksternal |
Waktu jeda | PLC atau pengontrol eksternal |
Suhu operasi | 0℃~ +50°C (Kondisi suhu rendah memerlukan minyak antibeku) |
Jumlah outlet | 1 atau 2 |
Kapasitas waduk | 0.3L, 0.5L, 0.7L |
Mengisi ulang | Removable reservoir/cartridge |
Pelumas | Gemuk kelas NLGI 000~2# |
Katup pelepas tekanan | Assembled |
Memulangkan | 7 mL/min |
Tekanan operasi maks. | 5.0 or 8.0 MPa |
Benang koneksi | Saluran keluar Φ6 |
Tegangan operasi | Tegangan 24VDC |
Sertifikasi | CE |
Sakelar level rendah | kontak NC |
Wiring
– Personnel qualifications: The wiring of the lubrication pump should be done by personnel qualified to do electrical work to ensure that the wiring is appropriate and safe.
– Polarity confirmation: The motor has polarity. In connecting the (+) and (-) wires, one should refer to the diagram for careful confirmation to avoid equipment failure due to incorrect polarity.
– Insulation measures: If the wires from the 24VDC power supply may contact the lubrication pump body, human body or surrounding objects, insulated wires must be used to prevent leakage and electric shock accidents.
– Ground connection: Connect the ground wire to the designated component to prevent leakage and electric shock. At the same time, to prevent fire caused by overcurrent, pay attention to the current limit. If the current exceeds 1.2A, the internal drive mechanism of the lubrication pump will return to the initial position.