Jinpinlub J200 CNC Lubrication Pump For LHL Grease Cartridge
Jinpinlub J200 lubrication pump is a small electric grease pump with the functions of convenient refilling, automatic detection of system pressure, automatic control of running time and interval time, and automatic pressure relief. It is small in size, reliable in operation.
Leírás
Jellemzők
– Operating pressure of this J200 lubrication pump is within the range of 5MPa to 8MPa, which provides stable high-pressure delivery of lubricant.
– The lubricant output from the lubrication pump is 7 ml per minute. This stable discharge helps for efficient operation of the lubrication system.
– The J20 lubrication pump has an IP54 protection rating, which means it has good dust and water resistance and can operate reliably in dusty and humid environments.
– The lubrication pump uses a DC 24V power supply. This design not only ensures the efficient operation of the pump, but also saves energy.
– The lubrication pump is equipped with an optional feed switch and lubricant level switch for user monitoring and operation. In addition, a specific removable grease cartridge is used.
Specifikáció
Modell | J200-3D |
Kenési idő | PLC vagy külső vezérlő |
Intervallum idő | PLC vagy külső vezérlő |
Üzemi hőmérséklet | 0℃~ +50°C (alacsony hőmérsékleti körülmények között fagyálló zsír szükséges) |
Az üzletek száma | 1 vagy 2 |
A tározó kapacitása | 0,3L, 0,5L, 0,7L |
Újratöltés | Kivehető tartály/patron |
Kenőanyag | Kenőzsírok NLGI 000~2# fokozatú |
Nyomáscsökkentő szelep | Összeszerelve |
Kisülés | 7 ml/perc |
Max. üzemi nyomás | 5,0 vagy 8,0 MPa |
Csatlakozó menet | Kimenet Φ6 |
Üzemi feszültség | 24VDC |
Tanúsítvány | CE |
Alacsony szint kapcsoló | NC érintkező |
Újratöltés
– If the lubrication pump does not discharge grease, there may be less grease remaining in the reservoir. If the valve does not discharge, the valve may be blocked.
– If there is air in the lubrication pump, exhaust it according to the instructions in the user manual. If there is air in the main pipeline, remove the end plug and operate the pump to exhaust.
– If the lubrication pump does not run, check the 24VDC power connection to ensure that the positive and negative poles of the wires are connected correctly. Even if the polarity is wrong, the pump will not be damaged, but it needs to be corrected.
– If the lubrication pump discharges low pressure, there may be leakage at the pump outlet or the machine pipeline connection parts. If the pipeline is damaged, it needs to be replaced.
– If the main pipeline pressure is not established, refer to the treatment of the lubrication pump not discharging grease. It may also be a power outage, pipeline damage or air in the system.