J200-5D Electric Lubrication Pump With Detachable Reservoir

J200 is an electric lubrication pump, a single-line lubrication system pump unit. Its key features include: power supply is DC24V, discharge volume is 7ml per minute, discharge pressure is 5MPa to 8MPa, suitable for lithium-based grease, IP54 protection grade.

Description

Caractéristiques

1. Power supply and start-up
The lubrication pump is powered by a 24V DC power supply. When the power is turned on, the motor starts. The rated current of the motor is 0.8A. Within the normal power supply range, the motor can run stably and provide power for the pump.

2. Lubricant delivery
The motor drives the lubrication pump to work. The lubricant is extracted from the storage container or cartridge through the internal structure including the plunger, gears, etc., and is delivered to each lubrication point of the machine through the pipeline at a displacement of 7ml/min.
During the delivery process, the discharge pressure can reach 8MPa.
3. Metering and control
In the lubrication system, the positive displacement distributor is used for precise control over the amount of lubricant to be delivered. This enables each lubrication point to acquire an appropriate amount of lubricant in order to achieve an optimized lubrication effect, rather than wasting lubricants. The running time and interval cycle of the lubrication pump are set by the timer installed on the machine and work under program setup.

Spécification

Modèle J200-5D
Temps de lubrification PLC or external controller
Intervalle de temps PLC or external controller
Température de fonctionnement 0℃~ +50°C (Low temperature conditions require antifreeze grease)
Nombre de points de vente 1 or 2
Capacité du réservoir 0.3L, 0.5L, 0.7L
Remplissage Removable reservoir/cartridge
Lubrifiant Graisses de grade NLGI 000~2#
Pressure relief valve Assembled
Décharge 7 mL/min
Pression de service max. 5.0 or 8.0 MPa
Fil de connexion Sortie Φ6
Tension de fonctionnement 24 V CC
Certification CE
Interrupteur de bas niveau Contact NC

Remplissage

– Replace the cartridge after the LHL in the cartridge is completely exhausted to avoid air entering the cartridge due to residual grease, which may cause malfunctioning of the lubrication pump.
– During the process of replacement of the cartridge, make sure that the surroundings are clean to avoid foreign objects like dust and impurities entering the lubrication pump body or cartridge.

– It is strictly forbidden to turn on the power when the cartridge is not installed in place or removed, otherwise the lubrication pump may inhale air or foreign objects.
– When replacing the cartridge, if you need to wipe around the oil suction port of the pump, you must use a clean cloth to prevent foreign objects from being sucked into the lubrication pump.
– Only use the specified LHL grease cartridge. Using other non-specified lubricants may cause lubrication system failure.
– Never fill the used empty grease cartridge with lubricant and use it again.

Manuels